logo menu
hero background

VacEase-500

TECHNICAL SPECIFICATION SHEET FOR VACEASE - 500:

1. Operating Range:
  • Vacuum: 1000 mbar to 5 mbar
  • Temperature Cooling: +95℃ to 5℃
  • Temperature Accuracy: +/-1℃
2. Construction:
  • Frame and Lid Material: 304 Stainless Steel
  • Dimensions: 2760 mm (H) x 1580 mm (W) x 2180 mm (L)
  • Weight: 1400 kg
3. Suitable trolley Dimensions:
  • Diameter: 1200 mm
  • Height: 1010 mm
4. Vacuum System:
  • Vacuum Pump: According to client’s needs
  • Motor Power: According to client’s needs
5. Control System:
  • System Control: PLC Siemens S7-1200
  • Human-Machine Interface: KTP 700
6. Temperature Measurement:
  • Product Temperature Measurement: Automatic insertion powered by pneumatic cylinder
7. Compliance:
  • European Regulations and Standards Compliant.

 

 

 

Contact Us